Known Issues in Prisma SD-WAN ION Release 5.6
Focus
Focus
Prisma SD-WAN

Known Issues in Prisma SD-WAN ION Release 5.6

Table of Contents
Learn about the known issues in Prisma SD-WAN ION Release 5.6.
Where Can I Use This?What Do I Need?
  • Prisma SD-WAN
  • Active Prisma SD-WAN license
Review the list of known issues for Prisma SD-WAN ION Release 5.6.
  • Known Issues in Prisma SD-WAN ION Release 5.6.13
  • Known Issues in Prisma SD-WAN ION Release 5.6.9
  • Known Issues in Prisma SD-WAN ION Release 5.6.7
  • Known Issues in Prisma SD-WAN ION Release 5.6.5

Known Issues in Prisma SD-WAN ION Release 5.6.13

The following list includes outstanding known issues specific to Prisma SD-WAN ION release 5.6.13.
Issue ID Description
CGSDW-4424VPN traffic from DC ION devices fails for packet sizes larger than 1800.
CGSDW-11472DC ION devices do not forward traffic to the management VLAN prefixes via the core peer router, if the management port on the core goes down.
CGSDW-12855Dynamic applications display SSL traffic incorrectly after TCP proxy restart. The workaround is to restart the Flow Controller.
CGSDW-13559Periodic flapping of the cellular data session is observed when using Verizon Wireless Network, Telstra, and possibly other carriers with direct to internet traffic on the ION 1200 devices.

Known Issues in Prisma SD-WAN ION Release 5.6.9

The following list includes outstanding known issues specific to Prisma SD-WAN ION release 5.6.9.
Issue ID Description
CGSDW-8564A BGP classic peer was dropping prefixes. Restarting the rtr-mgr process will fix this issue.

Known Issues in Prisma SD-WAN ION Release 5.6.7

Learn about the known issues in Prisma SD-WAN ION release 5.6.7.
The following list includes outstanding known issues specific to Prisma SD-WAN ION release 5.6.7.
Issue ID Description
CGSDW-12855TCP socket between TCPProxy and FC is broken post TCPProxy restart. The workaround is to restart the FC.
CGSDW-14456The fc-cp process crashes in the new primary device post HA failover.

Known Issues in Prisma SD-WAN ION Release 5.6.5

Learn about the known issues in Prisma SD-WAN ION release 5.6.5.
The following list includes outstanding known issues specific to Prisma SD-WAN ION release 5.6.5.
Issue ID Description
CGSDW-680RTR Manager is running at 100% when receiving a large number of BGP prefixes, the workaround is to reduce the number of prefixes the peer is advertising.
CGSDW-12113Branch backup ION device displays as partially online following Hood maintenance.