Known Issues in Prisma SD-WAN ION Release 6.4
Focus
Focus
Prisma SD-WAN

Known Issues in Prisma SD-WAN ION Release 6.4

Table of Contents

Known Issues in Prisma SD-WAN ION Release 6.4

Learn about the known issues in Prisma SD-WAN ION Release 6.4.
Where Can I Use This?What Do I Need?
  • Prisma SD-WAN
  • Prisma SD-WAN license
Review a list of known issues for Prisma SD-WAN ION Release 6.4.
To view the consolidated list of known issues across Prisma SD-WAN ION releases, see here.

Known Issues in Prisma SD-WAN ION Device Release 6.4.3

The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.3.
Issue IDDescription
CGSDW-36321The DHCP-relay forwards the DHCP server reply to an incorrect destination. This issue occurs when the network configuration contains overlapping IP addresses across multiple VRF instances.
CGSDW-36228The device does not use the configured VRF interface as the source interface for NTP synchronization.
CGSDW-35936Both Data Center ION devices advertise duplicate prefixes. This occurs when two branch sites can advertise the same prefix set to the DC cluster.
CGSDW-35452The ADEM process crashes multiple times when running regression scripts that test VRF interfaces.
CGSDW-33589The device does not add aggregated routes learned via BGP to the FIB. This occurs when the system receives a BGP aggregate that contains connected subnets or VLANs.

Known Issues in Prisma SD-WAN ION Device Release 6.4.2

The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.2.
Issue IDDescription
CGSDW-30788fp-rte corefile is generated in asymmetric LAN flow with specific policy.
CGSDW-27241After enabling logs for the flow controller, the logs are not rolling over correctly, thus using up all the space in the log directory.

Known Issues in Prisma SD-WAN ION Device Release 6.4.1

The following table lists the known issues in Prisma SD-WAN ION Device Release 6.4.1.
Issue IDDescription
CGSDW-30069 This issue is resolved in ION version 6.3.6ADEM probes for private applications fail when traffic routes over the secure fabric. The system incorrectly sends probe traffic to the direct internet path.
CGSDW-31654FC crashes at pan_sml_vm_set_field_flag() within the ml7 library.
CGSDW-24973Some advertised prefixes are not displayed for a DC ION device after changing the site mode from Control to Disabled and then back to Control.
CGSDW-23582OSPF routes are still advertised to the core BGP router even when the WAN paths for OSPF are deleted.