Upgrade ION 9000 Firmware for Device Version 5.6.x
Upgrade ION 9000 firmware.
If you have ION 9000 data center devices on
software version Release 5.6.x, upgrade the firmware driver that
is impacted due to enabling of the DPDK, by following the below
mentioned steps.
- From the CLI toolkit commands, stop the FC. Execute
the following command:debug process stop name=fcdebug process stop name=fc 9K# debug process stop name=fc Do you really want to stop fc [y/n]: y fc: stopped
- From the CLI toolkit command, execute the following command to upgrade the device firmware:
ion9000 upgrade-x722-fw
After the upgrade is complete, the device will reboot automatically.9K# ion9000 upgrade-x722-fw Will upgrade from 4.11 to 5.10 This will take about 20 minutes and then reboot the device DO NOT INTERRUPT THIS COMMAND ONCE IT STARTS Do not log out, shut down, or hit control-C. Ensure power is not removed during this process. Agree [Y/N]? Y Intel(R) Ethernet NVM Update Tool NVM Update version 1.35.42.7 Copyright (C) 2013 - 2020 Intel Corporation.i40e 0000:b7:00.0: Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected. i40e 0000:b7:00.0: Refer to the Intel(R) Ethernet Adapters and Devices User Guide for a list of supported modules. ...................................... [00:183:00:00]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Flash inventory started. Shadow RAM inventory started. Alternate MAC address is not set. Shadow RAM inventory finished. Flash inventory finished. OROM inventory started. OROM inventory finished. PHY NVM inventory started. PHY NVM inventory finished. ...................................... [00:183:00:03]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Device already inventoried. Update [00:183:00:00]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Creating backup images in directory: ECB90703D8CA. OROM not present on device - skipping FLB backup. Backup images created. Flash update started. |>.....................[ 0%]......................| i40e 0000:b7:00.0: Rx/Tx is disabled on this device because an unsupported SFP+ module type was detected. i40e 0000:b7:00.0: Refer to the Intel(R) Ethernet Adapters and Devices User Guide for a list of supported modules. |======================[100%]======================| NVM verification started. Shadow RAM verification started. |======================[100%]======================| Shadow RAM verification finished. Flash verification started. |======================[100%]======================| Flash verification finished. NVM verification finished. Flash update successful. Update security revisions [00:183:00:00]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Skipping update minimum security revisions. Checking update availability for next tool run. Config file doesn't have any OROM components specified for device 'X722'. Tool will use current device's combo set for the OROM update. Post update inventory [00:183:00:00]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Flash inventory started. Alternate MAC address is not set. Flash inventory finished. OROM inventory started. OROM inventory finished. No PHY NVM update taken - skipping inventory. [00:183:00:03]: Intel(R) Ethernet Connection X722 for 10GbE SFP+ Device already inventoried. Reboot is required to complete the update process. Broadcast message from root@90-000004-3218 (Wed Mar 2 00:09:07 2022): INIT: Sending processes the TERM signal 9K-FW-Upgrade# PLCM driver is not loaded. Stopping OpenBSD Secure Shell server: sshd. Stopping quagga watchdog daemon: watchquaggastart-stop-daemon: warning: failed to kill 4148: No such process. OK Stopping TCG TSS2 Access Broker and Resource Management daemon: tpm2-abrmd. Stopping TPM2 Monitoring Script daemon: tpm2abrmdscript pid: 4533 Waiting for tpm2abrmdscript to exit Stopping system message bus: dbus. Stopping DHCP server: dhcpd3No /usr/sbin/dhcpd found running; none killed. Unmounting fuse control filesystem. Unloading fuse module. Shutting down irqbalance: No irqbalance found running; none killed. done Stopping syslogd/klogd: No klogd found running; none killed. Stopping random number generator daemon. Kdump has been stopped. Stopping crond: OK Stopping S.M.A.R.T. daemon: smartd. Stopping network management services: snmpd snmptrapd. Stopping vmware tools daemon: start-stop-daemon: warning: failed to kill 4145: No such process FAIL Deconfiguring network interfaces... done. Stopping Quagga daemons: (!zebra) (!bgpd). Removing all routes made by zebra. Stopping watchdog daemon...Stopping Trusted Computing Script daemon: cat: /var/run/trouserscript.pid: No such file or directory trouserscript pid: cat: /var/run/trouserscript.pid: No such file or directory trouserscript not running Unmounting remote filesystems... Deactivating swap... Unmounting local filesystems... Rebooting... Nothing has been loaded! No kexec kernel loaded. Falling back to traditional reboot. reboot: Restarting system Version 2.20.1271. Copyright (C) 2020 American Megatrends, Inc. CloudGenix Model: ION 9000 Version: V111 Mfg:03/04/2020 Press Del or Esc to enter setup. Boot Bios: Primary BIOS Welcome to GRUB! no such device: DVT. Checking newer image (hd0,gpt6)/ 5.6.3-b11 ..................... licenses.tar.gz: okBooting hd0,gpt6 at 2022-03-02 00:10:08 Wednesday [INIT:DEBUG] early_setup sku519l [INITRD] 5.6.3-b11 Stopping system message bus: dbus. Starting system message bus: dbus. Starting TCG TSS2 Access Broker and Resource Management daemon: tpm2-abrmd. [VERIFY] cgnx-angrybird ......................... [INITRD] Switch root INIT: version 2Loading fuse module. Mounting fuse control filesystem. Starting udev Reboot-reason: x722 firmware upgrade to 5.10 INIT: Entering runlevel: 5 Operating in Non-Fips mode Configuring network interfaces... done. Removing stale PID file /var/run/dbus/pid. Starting system message bus: dbus. Starting random number generator daemon Initializing available sources Failed to init entropy source hwrng Enabling RDSEED rng support Initializing entropy source rdrand Starting OpenBSD Secure Shell server: sshd done. Starting Quagga daemons: zebra bgpd. Starting DHCP server: . Not starting irqbalance Starting syslogd/klogd: done daemon not start due to lack of /dev/watchdog No kdump kernel image found. Starting TCG TSS2 Access Broker and Resource Management daemon: tpm2-abrmd. TPM 2.0 device skipping starting DRIVE sda 3 Starting crond: OK Starting network management services: snmpd. Starting vmware tools daemon: OK Starting quagga watchdog daemon: watchquagga. c6xx 0000:68:00.0: Cannot use PF with IOMMU enabled ........................................... Stopping device qat_dev2 QAT running. Starting TPM2 Monitoring Script daemon: tpm2abrmdscript started. CloudGenix 5.6.3-b11 90-000004-3218 login: 90-000004-3218 login: admin1 Password: - From the CLI toolkit command, execute the following command to upgrade the device firmware: