set deviceconfig setting management
Description
Configure administrative
management session settings on the WildFire appliance. You can configure
timeouts to end administrative sessions if they are idle too long
and how many login retries (failed login attempts) it takes to lock
out an administrator.
Hierarchy Location
set deviceconfig setting
Syntax
management {
idle-timeout {0 | <value>}
admin-lockout {
failed-attempts <value>
lockout-time <value>
}
}
Options
+ idle-timeout —
Default administrative session idle timeout in minutes. Configure
an idle timeout from 1-1440 minutes, or set the timeout value to
0 (zero) to never timeout the session.
> admin-lockout —
Configure the number of failed-attempts to
login to the appliance before the administrator is locked out of
the system (0-10), and the lockout-time in
minutes (0-60) to lock out an administrator if the administrator
crosses the failed-attempts threshold.
Sample Output
management {
idle-timeout 0;
admin-lockout {
failed-attempts 3;
lockout-time 5;
}
}