: Configure Prisma SD-WAN to Export IPFIX Records
Focus
Focus

Configure Prisma SD-WAN to Export IPFIX Records

Table of Contents

Configure Prisma SD-WAN to Export IPFIX Records

Learn how to configure Prisma SD-WAN to export IPFIX records.
Configure the Prisma SD-WAN ION device to export IPFIX flow data to LiveNX.
  1. Enable SNMP configuration on the ION device to allow LiveNX to discover the ION device.
    The ION device supports both SNMP v2 and v3.
  2. Configure IPFIX to apply to all sites and devices globally or configure IPFIX locally for an ION device to override the global IPFIX configuration.
  3. Once the IPFIX profiles are created and attached to the Prisma SD-WAN ION devices, the ION devices start exporting IPFIX flow data.
    By default, LiveNX listens for IPFIX flow data on UDP port 2055. You can change the IPFIX listening port on LiveNX. Refer to instructions on changing the IPFIX listening port on LiveNX.

Change the IPFIX Listening Port on LiveNX

  1. Navigate to SettingsLiveNX Properties.
  2. Change the value for the field flow.collector.netflow.port.