Known Issues in Panorama Plugin for VMware NSX 3.2.3
Table of Contents
Expand all | Collapse all
-
-
-
-
- Features Introduced in Zero Touch Provisioning 2.0
- Known Issues in the Zero Touch Provisioning 2.0.4 Release
- Known Issues in the Zero Touch Provisioning 2.0.3 Release
- Known Issues in the Zero Touch Provisioning 2.0.2 Release
- Known Issues in the Zero Touch Provisioning 2.0.1 Release
- Known Issues in the Zero Touch Provisioning 2.0.0 Release
- Limitations
-
-
Known Issues in Panorama Plugin for VMware NSX 3.2.3
The following list describes known issues
in the Panorama plugin for VMware NSX 3.2.3.
PLUG-5994
After a Panorama HA failover, the service
manager might become Out of Sync with the
message Services list is missing on Panorama...Downloading
new one.
Workaround: Execute the command request plugins reset-plugin only plugin plugin-name vmware_nsx on
Panorama.
PLUG-5987
If you downgrade to the Panorama plugin
for VMware NSX 3.1.0 after creating an NSX-T service definition
with Health Check as Enabled (default) while
the Panorama plugin for VMware NSX 3.2.0 is installed on Panorama,
the service definition create on plugin 3.2.0 will be Out-of-Sync after
downgrade due to a mismatch in Health Check configuration (changed
to Disabled).
Workaround: Set Health Check to Enable on
the out-of-sync service definition and Commit your
changes.
PLUG-5756
If you have two Panorama appliances installed
in an HA with multiple plugins installed, Panorama might not receive
updated IP-tag information after failover. This occurs when one
of the installed plugins is not configured on Panorama because Panorama is
waiting to receive an IP address update for the unconfigured plugin
or plugins.
Workaround: Unisntall the unconfigured plugin or plugins.
It is recommended that you do not install a plugin that you do not
plan to configure right away.
Alternatively, you can use the following commands to work around
this issue. Execute the command request plugins dau plugin-name <plugin-name> unblock-device-push yes for
each unconfigured plugin on each Panorama instance to prevent Panorama
from waiting for updates for disabled plugins. If you configure the
other plugins, execute the command request plugins dau plugin-name <plugin-name> unblock-device-push no.
If you do not, your firewalls may lose some IP-tag information.
The commands describe are not persistent and must be used
again for any subsequent failover events.
PLUG-5692
When you enable Device Certificate and
add PIN ID and PIN value to an existing NSX-V service definition
that had Device Certificate disabled, the PIN ID and PIN value are
not pushed to NSX-V Manager.
PLUG-5475
If Panorama HA failover occurs while
Panorama is disconnected from NSX-V Manager, the Service Manager
section of NSX-V Manager will display the IP address of the formerly
active (now passive) Panorama peer. This occurs after failover and
the connection between Panorama and NSX-V Manager is reestablished.
Workaround: Perform a manual config sync in Panorama to
display the correct Panorama IP address in NSX-V Manager.
PLUG-2959
Panorama incorrectly allows the modification
of the NSX-T plugin configuration while in a suspended state. Do
not attempt to modify the NSX-T plugin configuration on a suspended
Panorama; this action is not supported.
PLUG-2950
After a Panorama failover event, if there
are some configuration objects in NSX-T Manager but not Panorama,
you must manually remove those objects from NSX-T Manager.
Workaround: Contact VMware for information about manually
removing the objects from NSX-T Manager.
PLUG-2767
In a Panorama HA pair, NSX-T plugin configuration
is not automatically synchronized to the passive Panorama if the
passive Panorama comes up after the active Panorama.
Workaround: On the Panorama dashboard, Synchronize to
Peer on the HA widget.
PLUG-2630
You cannot use a service-definition across
multiple service managers; each service definition is mapped to
a unique service manager.
PLUG-2226
When a device group is added or removed
from an existing notify group, existing dynamic address groups are
not updated to reflect the device group change.
Workaround: Synchronize Dynamic Objects on PanoramaVMwareNSX-TService
Manager to update dynamic address groups.
PLUG-1787
The connection between NSX-T Manager
and Panorama goes Out of Sync if you change
the NSX-T Manager IP address configured on Panorama.
Workaround: To change the NSX-T Manager IP address, you
must completely reconfigure and reinstall your VM-Series firewall
on NSX-T deployment. If there are active firewall in your deployment,
you must remove those before deleting the service manager. You must
delete the Service Manager configuration from Panorama and add it again
with the new IP address. To delete the Service Manager, you must
remove the rest of your VM-Series on NSX-T configuration from Panorama.
PLUG-1618
You can open the NSX Manager Objects
window from PanoramaVMwareNSX-TService Managers but
displays no information.