Learn how to troubleshoot IPFIX integration between Prisma
SD-WAN and LiveAction.
If you do not see IPFIX flows on LiveNX, use
the following verification steps:
Ensure that you configure the same listening port
number on both LiveNX and Prisma SD-WAN.
Check if the Prisma SD-WAN ION device has established
a session with the IPFIX collector.
Check if flow records are exported from the Prisma SD-WAN
ION device to the IPFIX collector.
Limitations with LiveAction Integration
IPFIX
flow information elements that are not IANA standard elements are
currently shown as Unidentified on LiveNX.
These flow elements will be integrated with LiveNX in a phased manner.
LiveNX currently shows vendor as Unknown for
Prisma SD-WAN ION devices. This will be fixed in the upcoming releases
of LiveNX and will not affect current reporting and monitoring.