The following lists the PA-5200 Series
firewall hardware compliance statements:
VCCI
This section provides the compliance statement
for the Voluntary Control Council for Interference by Information
Technology Equipment (VCCI), which governs radio frequency emissions
in Japan.
The following information is in accordance to VCCI
Class A requirements:
Translation:
This is a Class A product. In a domestic environment this product
may cause radio interference, in which case the user may be required
to take corrective actions.
NEBS Requirements
The following lists the Network Equipment
Building System (NEBS) requirements for PA-5200 Series firewalls.
The firewall is intended to be installed in a Network Telecommunication
Facility (Central Office) as part of a Common Bonding Network (CBN)
or Isolated Bonding Network (IBN). Bare conductors must be coated
with an appropriate antioxidant compound before crimp connections
are made. All unplated connectors, braided strap, and bus bars must
be brought to a bright finish and then coated with an antioxidant
before they are connected.
Fastening hardware must be compatible
with the materials being joined and must preclude loosening, deterioration,
and electrochemical corrosion of the hardware and the joined materials.
The firewall is suitable for connection to the Central Office
or Customer Premise Equipment (CPE).
The DC battery return wiring on the firewall must be connected
as an isolated DC return (DC-I).
The
intra-building ports (RJ-45 Ethernet ports, AUX ports, HA ports,
and the MGT port) of the equipment or subassembly are suitable for
connection to only intra-building or unexposed wiring or cabling.
The intrabuilding port(s) of the equipment or subassembly must not
be metallically connected to interfaces that connect to the Outside
Plant (OSP) or its wiring. These interfaces are designed for use
as intra-building interfaces only (Type 2 or Type 4 ports as described
in GR-1089-CORE, Issue 6) and require isolation from the exposed
OSP cabling. The addition of primary protectors is not sufficient
protection to connect these interfaces metallically to OSP wiring.The
firewall must be connected to an external Special Protection Device
(SPD) when installed and connected to commercial AC power.
The
firewall must be connected to an external Special Protection Device
(SPD) when installed and connected to commercial AC power.
BSMI EMC Statement
User warning: This is a Class A
product. When used in a residential environment it may cause radio
interference. In this case, the user will be required to take adequate
measures.
Manufacturer—Flextronics International.
Country of Origin—Made in the USA with parts of domestic
and foreign origin.
CE (European Union (EU) Electromagnetic Compatibility Directive)
This
device is herewith confirmed to comply with the requirements set
out in the Council Directive on the Approximation of the Laws of
the Member States relating to Electromagnetic Compatibility Directive
(2014/30/EU).
The above product conforms with Low Voltage
Directive 2014/35/EU and complies with the requirements relating
to electrical equipment designed for use within certain voltage limits.